HYDRAULIC FILTRATION

Inline Filters for the separation of solids and pressure fluids and lubricating oils

Hengst Inline Filters are used in hydraulic systems for separating solid materials from the hydraulic fluids and lubricating oils.  They are intended for attachment in pipelines.

110LE(N)

  • Cyclone effect
  • Forcing spring for filter element change
  • Drain plug from NG160
  • Optional test ports from NG160
  • Opional hydraulic connections with UNF thread
Workplace Nominal size 0040 – 0400/td>
Workplace Maximum volume flow in l/min. 450
Workplace Maximum operating pressure in bar 110″
Workplace Replacement filter element: 2.0040 – 0400
Data Sheets:
Workplace EN RD 51448 – Click Here
Workplace ES RD 51448 – Click Here
Workplace FR RD 51448- Click Here
Workplace IT RD 51448- Click Here
Workplace PT RD 51448 – Click Here
Workplace ZH RD 51448 – Click Here

More information – Click Here

Find the right filter in only a few steps with the our Fit4Filter search tool.

Easily identify other major filter manufacturers and cross reference to the equivalent Hengst Part number:

And many more major filter manufacturers. Click here to search our Fit4Filter tool.

  •  Cyclone effect
  • Only 350, 445 NG0630 (split filter bowl on request) standard from NG1000 upwards (simplified maintenance)
  • Drain plug from NG0160
  • Optional hydraulic connections with UNF thread
  • Only 445 LEN top outlet optional (outlet closed opposite)
Workplace Nominal size 0040 – 0400
Workplace Maximum volume flow in l/min. 450
Workplace Maximum operating pressure in bar 250
Workplace Replacement filter element: 2.0040 – 0400
Data Sheets:
Workplace RD 5142- Click Here

More information – Click Here

Find the right filter in only a few steps with the our Fit4Filter search tool.

Easily identify other major filter manufacturers and cross reference to the equivalent Hengst Part number:

And many more major filter manufacturers. Click here to search our Fit4Filter tool.

245LE(N)

350LE(N)

  • Cyclone effect
  • Only 350, 445 NG0630 (split filter bowl on request) standard from NG1000 upwards (simplified maintenance)
  • Drain plug from NG0160
  • Optional hydraulic connections with UNF thread
  • Only 445 LEN top outlet optional (outlet closed opposite)
Workplace Nominal size 0040 – 1000
Workplace Maximum volume flow in l/min. 700
Workplace Maximum operating pressure in bar 350
Workplace Replacement filter element: 2.0040 – 1000
Data Sheets:
Workplace RD 51422- Click Here

More information – Click Here

Find the right filter in only a few steps with the our Fit4Filter search tool.

Easily identify other major filter manufacturers and cross reference to the equivalent Hengst Part number:

And many more major filter manufacturers. Click here to search our Fit4Filter tool.

  • Cyclone effect
  • Only 350, 445 NG0630 (split filter bowl on request) standard from NG1000 upwards (simplified maintenance)
  • Drain plug from NG0160
  • Optional hydraulic connections with UNF thread
  • Only 445 LEN top outlet optional (outlet closed opposite)
Workplace Nominal size 0040 – 1000
Workplace Maximum volume flow in l/min. 700
Workplace Maximum operating pressure in bar 450
Workplace Replacement filter element: 2.0040 – 1000
Data Sheets:
Workplace RD 51423- Click Here

More information – Click Here

Find the right filter in only a few steps with the our Fit4Filter search tool.

Easily identify other major filter manufacturers and cross reference to the equivalent Hengst Part number:

And many more major filter manufacturers. Click here to search our Fit4Filter tool.

445LE(N)

40FLE(N)

  • Filter element change possible without tools
  • Filter element change possible from above
  • Optical maintenance indicator
  • Drain plug
  • Bypass valve at the highest position of the filter cover (no gas / air accumulation)
Workplace Nominal size 0045 – 0270 / 0160 – 1000
Workplace Maximum volume flow in l/min. 2000
Workplace Maximum operating pressure in bar 40
Workplace Replacement filter element: 1.0160 – 0270
Data Sheets:
Workplace RD 51401- Click Here

More information – Click Here

Find the right filter in only a few steps with the our Fit4Filter search tool.

Easily identify other major filter manufacturers and cross reference to the equivalent Hengst Part number:

And many more major filter manufacturers. Click here to search our Fit4Filter tool.

  • Filter element change possible from above
  • Optical maintenance indicator
  • Drain screw for complete emptying of the filter
  • Bypass valve at the highest position of the filter cover (no gas / air accumulation)
Workplace Nominal size 0045 – 0120 / 0610 – 0630
Workplace Maximum volume flow in l/min. 1700
Workplace Maximum operating pressure in bar 100
Workplace Replacement filter element: 2.0058 – 0059
Data Sheets:
Workplace RD 51402- Click Here

More information – Click Here

Find the right filter in only a few steps with the our Fit4Filter search tool.

Easily identify other major filter manufacturers and cross reference to the equivalent Hengst Part number:

And many more major filter manufacturers. Click here to search our Fit4Filter tool.

100FLE / FLE(N)

  • Visual maintenance indicators
  • Drain plug
  • Bypass valve at highest position of filter cover (no gas / air accumulation)
  • Optional vent valve from NG4000 upwards
  • Optional from NG4000 lid lifting device
Workplace Nominal size 0045 – 0270 / 0160 – 1000
Workplace Maximum volume flow in l/min. 2000
Workplace Maximum operating pressure in bar 40
Workplace Replacement filter element: 2.0058 – 0059
Data Sheets:
Workplace RD 51403- Click Here

More information – Click Here

Find the right filter in only a few steps with the our Fit4Filter search tool.

Easily identify other major filter manufacturers and cross reference to the equivalent Hengst Part number:

And many more major filter manufacturers. Click here to search our Fit4Filter tool.